With that in mind the height of the chimney should be at least 15 feet from the floor of the fireplace to the top of the flue.
Flue size kitchen chimney size chart.
Quality chimney liner material that meets astm and excels in freeze thaw environments.
The velocity of air and flue gas in a smaller furnace should not exceed 2 m s.
The rule of thumb is a 1 10 ratio meaning that the fireplace opening can be 10 times as large as the flue tile cross section.
For example you could vent a 6 inch stove into an insulated chimney that is 8 inches in diameter.
An appliance operating at a steady state efficiency over 83 percent may be.
You need to measure the outside length and width of your flue in order to cap an oval chimney termination.
Once you have that number you can search for a slip in chimney cap of the same size.
A q v 3 where.
A cross sectional area of chimney m 2 q volume of flue gases at chimney temperature m 3 s v velocity m s.
This article series provides information about masonry fireplaces.
10 3 32 chimney sizes for neutral draft equipment.
A 6 inch stove requires a 6 inch flue.
To provide adequate draft and safe venting of combustion products the chimney flue for a fireplace has to be adequate in size or cross sectional area.
Figuring out the proper size for your chimney flue can seem like a challenge.
Design velocities of larger furnaces should not exceed 10 m s.
Required chimney area can be calculated as.
For example an 8 x 8 square nominal clay chimney flue tile liner has inside dimensions of 6 3 4 x 6 3 4.
Venting a wood stove.
Single flue chimneys with oval flues.
In most cases a step up is also fine.
The rule of thumb for sizing a chimney liner is that you never want it to be smaller than the appliance exhaust hole and you don t want the liner to be three times the area of the exhaust hole of the appliance.
Net flue gas temperature rise above ambient and flue gas composition co2.
Fireplace flue size specifications relation of fireplace size to flue opening dimensions table of required chimney flue size and flue dimensions for masonry fireplaces.
Solving your chimney s math.
As a general rule the diameter of the chimney should match the flue collar on your wood stove.
31 chimney sizes for appliances needing draft.
32 to 36 wide 25 to 29 high it is important for the size of the chimney to be correctly calculated to match the fireplace opening.
Dimensions for square rectangular and round clay flue liner.
Chimney height also plays a role and taller chimneys generally draft better than shorter ones.
The venting capacity of a rectangular or square masonry flue if translated directly into actual or measured square inches of cross section is less than a round chimney flue of the same square inches of venting capacity.